{"id":7958,"date":"2026-01-26T03:18:55","date_gmt":"2026-01-26T03:18:55","guid":{"rendered":"https:\/\/risentric.com\/definition-des-parametres-des-appareillages-de-commutation\/"},"modified":"2026-05-25T14:31:11","modified_gmt":"2026-05-25T14:31:11","slug":"definition-des-parametres-des-appareillages-de-commutation","status":"publish","type":"post","link":"https:\/\/risentric.com\/fr\/definition-des-parametres-des-appareillages-de-commutation\/","title":{"rendered":"D\u00e9finition des param\u00e8tres des appareillages de commutation"},"content":{"rendered":"\n<div class=\"wp-block-uagb-container uagb-block-3464e358 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<p>-Pour les param\u00e8tres li\u00e9s aux enveloppes, tels que l\u2019indice IP, la conception structurelle et les conditions d\u2019installation, veuillez vous r\u00e9f\u00e9rer \u00e0 :<br\/><a href=\"https:\/\/risentric.com\/fr\/parametres-de-larmoire-lenceinte\/\" data-type=\"post\" data-id=\"6841\"><strong>Param\u00e8tres des armoires et enveloppes<\/strong><br\/><\/a>-Pour la mise en \u0153uvre pratique des param\u00e8tres abord\u00e9s dans cet article, consultez la page produits des appareillages de commutation de Risentric :<br\/><strong><a href=\"https:\/\/risentric.com\/fr\/produits-et-services\/appareillage-armoire-panneau\/\" data-type=\"link\" data-id=\"https:\/\/risentric.com\/products-services\/switchgear-categories\/\">Produits d\u2019appareillage de commutation<\/a><\/strong><\/p>\n\n\n\t\t\t\t<div class=\"wp-block-uagb-table-of-contents uagb-toc__align-left uagb-toc__columns-1 uagb-toc__collapse uagb-block-92646356      uagb-toc__collapse--list\"\n\t\t\t\t\tdata-scroll= \"1\"\n\t\t\t\t\tdata-offset= \"30\"\n\t\t\t\t\tstyle=\"\"\n\t\t\t\t>\n\t\t\t\t<div class=\"uagb-toc__wrap\">\n\t\t\t\t\t\t<div class=\"uagb-toc__title\">\n\t\t\t\t\t\t\t<strong>Table Of Contents<\/strong>\t\t\t\t\t\t\t\t\t\t\t\t\t<svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewBox= \"0 0 384 512\"><path d=\"M192 384c-8.188 0-16.38-3.125-22.62-9.375l-160-160c-12.5-12.5-12.5-32.75 0-45.25s32.75-12.5 45.25 0L192 306.8l137.4-137.4c12.5-12.5 32.75-12.5 45.25 0s12.5 32.75 0 45.25l-160 160C208.4 380.9 200.2 384 192 384z\"><\/path><\/svg>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"uagb-toc__list-wrap uagb-toc__list-hidden\">\n\t\t\t\t\t\t<ol class=\"uagb-toc__list\"><li class=\"uagb-toc__list uagb-toc__list--expandable\"><span class=\"list-open\" role=\"button\" tabindex=\"0\" aria-expanded=\"true\"><\/span><a href=\"#param\u00e8tres-li\u00e9s-au-courant\" class=\"uagb-toc-link__trigger\">Param\u00e8tres li\u00e9s au courant<\/a><ul class=\"uagb-toc__list\"><li class=\"uagb-toc__list \"><a href=\"#1-courant-nominal-in\" class=\"uagb-toc-link__trigger\">1. Courant nominal (In)<\/a><li class=\"uagb-toc__list\"><li class=\"uagb-toc__list \"><a href=\"#2-courant-de-r\u00e9glage-du-d\u00e9lai-long-ir\" class=\"uagb-toc-link__trigger\">2. Courant de r\u00e9glage du d\u00e9lai long (Ir)<\/a><li class=\"uagb-toc__list\"><li class=\"uagb-toc__list \"><a href=\"#3-courant-de-r\u00e9glage-du-d\u00e9lai-court-isd\" class=\"uagb-toc-link__trigger\">3. Courant de r\u00e9glage du d\u00e9lai court (Isd)<\/a><li class=\"uagb-toc__list\"><li class=\"uagb-toc__list \"><a href=\"#4-courant-de-d\u00e9clenchement-instantan\u00e9-ii\" class=\"uagb-toc-link__trigger\">4. Courant de d\u00e9clenchement instantan\u00e9 (Ii)<\/a><li class=\"uagb-toc__list\"><li class=\"uagb-toc__list \"><a href=\"#5-pouvoir-de-coupure-ultime-en-court-circuit-nominal-icu\" class=\"uagb-toc-link__trigger\">5. Pouvoir de coupure ultime en court-circuit nominal (Icu)<\/a><li class=\"uagb-toc__list\"><li class=\"uagb-toc__list \"><a href=\"#6-pouvoir-de-coupure-en-court-circuit-de-service-nominal-ics\" class=\"uagb-toc-link__trigger\">6. Pouvoir de coupure en court-circuit de service nominal (Ics)<\/a><li class=\"uagb-toc__list\"><li class=\"uagb-toc__list \"><a href=\"#7-courant-admissible-de-courte-dur\u00e9e-nominal-icw\" class=\"uagb-toc-link__trigger\">7. Courant admissible de courte dur\u00e9e nominal (Icw)<\/a><li class=\"uagb-toc__list\"><li class=\"uagb-toc__list \"><a href=\"#8-courant-de-cr\u00eate-admissible-nominal-ipk\" class=\"uagb-toc-link__trigger\">8. Courant de cr\u00eate admissible nominal (Ipk)<\/a><li class=\"uagb-toc__list\"><li class=\"uagb-toc__list \"><a href=\"#9-courant-de-calibre-du-ch\u00e2ssis-du-disjoncteur-inm\" class=\"uagb-toc-link__trigger\">9. Courant de calibre du ch\u00e2ssis du disjoncteur (Inm)<\/a><li class=\"uagb-toc__list\"><li class=\"uagb-toc__list \"><a href=\"#10-courant-nominal-de-groupe-ing\" class=\"uagb-toc-link__trigger\">10. Courant nominal de groupe (Ing)<\/a><li class=\"uagb-toc__list\"><li class=\"uagb-toc__list \"><a href=\"#11-courant-nominal-de-circuit-unique-inc\" class=\"uagb-toc-link__trigger\">11. Courant nominal de circuit unique (Inc)<\/a><li class=\"uagb-toc__list\"><li class=\"uagb-toc__list \"><a href=\"#12-courant-de-court-circuit-conditionnel-nominal-icc\" class=\"uagb-toc-link__trigger\">12. Courant de court-circuit conditionnel nominal (Icc)<\/a><\/li><\/ul><\/li><li class=\"uagb-toc__list uagb-toc__list--expandable\"><span class=\"list-open\" role=\"button\" tabindex=\"0\" aria-expanded=\"true\"><\/span><a href=\"#param\u00e8tres-de-tension-et-de-fr\u00e9quence\" class=\"uagb-toc-link__trigger\">Param\u00e8tres de tension et de fr\u00e9quence<\/a><ul class=\"uagb-toc__list\"><li class=\"uagb-toc__list \"><a href=\"#1-tension-nominale-du-syst\u00e8me-un\" class=\"uagb-toc-link__trigger\">1. Tension nominale du syst\u00e8me (Un)<\/a><li class=\"uagb-toc__list\"><li class=\"uagb-toc__list \"><a href=\"#2-tension-de-fonctionnement-nominale-ue\" class=\"uagb-toc-link__trigger\">2. Tension de fonctionnement nominale (Ue)<\/a><li class=\"uagb-toc__list\"><li class=\"uagb-toc__list \"><a href=\"#3-tension-disolement-nominale-ui\" class=\"uagb-toc-link__trigger\">3. Tension d\u2019isolement nominale (Ui)<\/a><li class=\"uagb-toc__list\"><li class=\"uagb-toc__list \"><a href=\"#4-tension-de-tenue-aux-chocs-nominaux-uimp\" class=\"uagb-toc-link__trigger\">4. Tension de tenue aux chocs nominaux (Uimp)<\/a><li class=\"uagb-toc__list\"><li class=\"uagb-toc__list \"><a href=\"#5-fr\u00e9quence-nominale-fnf\" class=\"uagb-toc-link__trigger\">5. Fr\u00e9quence nominale (fn\u00a0\/\u00a0f)<\/a><\/li><\/ul><\/li><\/ul><\/li><li class=\"uagb-toc__list uagb-toc__list--expandable\"><span class=\"list-open\" role=\"button\" tabindex=\"0\" aria-expanded=\"true\"><\/span><a href=\"#faq-d\u00e9finition-des-param\u00e8tres-de-lappareillage\" class=\"uagb-toc-link__trigger\">FAQ (D\u00e9finition des param\u00e8tres de l\u2019appareillage)<\/a><ul class=\"uagb-toc__list\"><li class=\"uagb-toc__list \"><a href=\"#1-que-sont-les-param\u00e8tres-de-lappareillage\" class=\"uagb-toc-link__trigger\">1) Que sont les \u00ab param\u00e8tres de l\u2019appareillage \u00bb ?<\/a><li class=\"uagb-toc__list\"><li class=\"uagb-toc__list \"><a href=\"#2-quelle-est-la-diff\u00e9rence-entre-in-et-inm\" class=\"uagb-toc-link__trigger\">2) Quelle est la diff\u00e9rence entre In et Inm ?<\/a><li class=\"uagb-toc__list\"><li class=\"uagb-toc__list \"><a href=\"#3-quelle-est-la-diff\u00e9rence-entre-in-et-ir\" class=\"uagb-toc-link__trigger\">3) Quelle est la diff\u00e9rence entre In et Ir ?<\/a><\/ul><\/ul><\/ul><\/ol>\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">Param\u00e8tres li\u00e9s au courant<\/h3>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-1c1c95ec wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/risentric.com\/wp-content\/uploads\/2026\/01\/Current-Related-Parameters-1024x683.webp ,https:\/\/risentric.com\/wp-content\/uploads\/2026\/01\/Current-Related-Parameters.webp 780w, https:\/\/risentric.com\/wp-content\/uploads\/2026\/01\/Current-Related-Parameters.webp 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/risentric.com\/wp-content\/uploads\/2026\/01\/Current-Related-Parameters-1024x683.webp\" alt=\"Relatif au courant\" class=\"uag-image-10570\" width=\"600\" height=\"400\" title=\"Relatif au courant\" loading=\"lazy\" role=\"img\"><\/figure><\/div>\n\n\n\n<h4 class=\"wp-block-heading\">1. Courant nominal (In)<\/h4>\n\n\n\n<p><strong>Unit\u00e9<\/strong>\u00a0: Amp\u00e8re (A)<br\/><strong>D\u00e9finition<\/strong>\u00a0: Le courant que l\u2019appareil peut supporter en continu dans des conditions sp\u00e9cifi\u00e9es, assurant un fonctionnement s\u00fbr, stable et efficace.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">2. Courant de r\u00e9glage du d\u00e9lai long (Ir)<\/h4>\n\n\n\n<p><strong>Unit\u00e9<\/strong>\u00a0: A<br\/><strong>D\u00e9finition<\/strong>\u00a0: <br\/>Le courant de fonctionnement maximal que le disjoncteur peut supporter en continu.<br\/><strong>Comportement de fonctionnement<\/strong>\u00a0:<br\/>Lorsque le courant d\u00e9passe Ir, le disjoncteur ne se d\u00e9clenche pas imm\u00e9diatement\u00a0; il ne se d\u00e9clenchera qu\u2019apr\u00e8s un certain d\u00e9lai. Par exemple\u00a0: In\u00a0=\u00a0100\u00a0A, Ir\u00a0=\u00a0100\u00a0A, courant r\u00e9el\u00a0=\u00a0120\u00a0A. Dans ce cas, il peut se d\u00e9clencher apr\u00e8s des dizaines de secondes ou plusieurs minutes. Il prot\u00e8ge principalement les c\u00e2bles et les moteurs, et emp\u00eache les dommages de surchauffe \u00e0 long terme de l\u2019\u00e9quipement.  <\/p>\n\n\n\n<h4 class=\"wp-block-heading\">3. Courant de r\u00e9glage du d\u00e9lai court (Isd)<\/h4>\n\n\n\n<p><strong>Unit\u00e9<\/strong>\u00a0: kA<br\/><strong>D\u00e9finition<\/strong>\u00a0: <br\/>Un niveau de courant \u00e9lev\u00e9 qui est autoris\u00e9 pendant un court d\u00e9lai.<br\/><strong>Comportement de fonctionnement<\/strong>\u00a0:<br\/>Compar\u00e9 \u00e0 Ir, Isd a un d\u00e9lai beaucoup plus court. Il est g\u00e9n\u00e9ralement r\u00e9gl\u00e9 \u00e0 plusieurs fois le courant nominal (une plage r\u00e9glable courante est d\u2019environ 2 \u00e0 10\u00a0\u00d7\u00a0In ou plus), avec un d\u00e9lai g\u00e9n\u00e9ralement de quelques dizaines \u00e0 des centaines de millisecondes. <\/p>\n\n\n\n<h4 class=\"wp-block-heading\">4. Courant de d\u00e9clenchement instantan\u00e9 (Ii)<\/h4>\n\n\n\n<p><strong>Unit\u00e9<\/strong>\u00a0: kA<br\/><strong>D\u00e9finition<\/strong>\u00a0: <br\/>Protection de d\u00e9clenchement instantan\u00e9 pour les d\u00e9fauts de court-circuit graves.<br\/><strong>Comportement de fonctionnement<\/strong>\u00a0:<br\/>Il est plus rapide qu\u2019Isd et est \u00e9galement d\u00e9clench\u00e9 par un courant excessif. Lorsque le courant atteint 8 \u00e0 15\u00a0\u00d7\u00a0In (MCB) ou 10 \u00e0 20\u00a0\u00d7\u00a0In (MCCB\/ACB), il se d\u00e9clenche imm\u00e9diatement, g\u00e9n\u00e9ralement en quelques millisecondes. <\/p>\n\n\n\n<h4 class=\"wp-block-heading\">5. Pouvoir de coupure ultime en court-circuit nominal (Icu)<\/h4>\n\n\n\n<p><strong>Unit\u00e9<\/strong>\u00a0: kA<br\/><strong>D\u00e9finition<\/strong>\u00a0: <br\/>Le courant de court-circuit maximal que le disjoncteur peut interrompre une fois\u00a0; apr\u00e8s l\u2019interruption, il n\u2019est pas garanti qu\u2019il reste utilisable.<br\/><strong>Comportement de fonctionnement<\/strong>\u00a0:<br\/>Icu est la limite maximale absolue que le disjoncteur peut interrompre, pas une \u00ab\u00a0zone de confort de fonctionnement s\u00fbre\u00a0\u00bb. Supposons qu\u2019un disjoncteur ait Icu\u00a0=\u00a0100\u00a0kA, et qu\u2019un court-circuit se produise \u00e0 un certain point\u00a0: Si le courant de d\u00e9faut I &lt; Icu, le disjoncteur se d\u00e9clenchera selon les fonctions de protection Ir, Isd et Ii. Les contacts s\u2019ouvrent, l\u2019arc est \u00e9tir\u00e9 et guid\u00e9 dans la chambre d\u2019extinction d\u2019arc, l\u2019arc est \u00e9teint et le circuit est interrompu en toute s\u00e9curit\u00e9. Si le courant de d\u00e9faut d\u00e9passe Icu, le courant excessif peut endommager la chambre d\u2019extinction d\u2019arc interne, causant des risques d\u2019arc \u00e9lectrique ou d\u2019explosion.   <br\/><strong>Appareil courant<\/strong>\u00a0: <br\/>Disjoncteur<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">6. Pouvoir de coupure en court-circuit de service nominal (Ics)<\/h4>\n\n\n\n<p><strong>Unit\u00e9<\/strong>\u00a0: kA<br\/><strong>D\u00e9finition<\/strong>\u00a0: <br\/>Le disjoncteur peut interrompre \u00e0 ce niveau de court-circuit et rester en service par la suite.<br\/><strong>Relation avec Ics<\/strong>\u00a0: Ics\u00a0=\u00a025\u00a0%, 50\u00a0%, 75\u00a0% ou 100\u00a0%\u00a0\u00d7\u00a0Icu<br\/><strong>Appareil courant<\/strong>\u00a0: <br\/>Disjoncteur<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">7. Courant admissible de courte dur\u00e9e nominal (Icw)<\/h4>\n\n\n\n<p><strong>Unit\u00e9<\/strong>\u00a0: kA (avec dur\u00e9e t\u00a0: 1\u00a0s\u00a0\/\u00a03\u00a0s\u00a0\/\u00a00,5\u00a0s)<br\/><strong>D\u00e9finition<\/strong>\u00a0: <br\/>Le courant que l\u2019\u00e9quipement peut supporter dans des conditions de court-circuit sans interruption (ne supportant que).<br\/><strong>Comportement de fonctionnement<\/strong>\u00a0:<br\/>Par exemple, Icw\u00a0=\u00a0100\u00a0kA\u00a0\/\u00a01\u00a0s signifie que l\u2019\u00e9quipement peut supporter 100\u00a0kA pendant 1\u00a0seconde dans des conditions de court-circuit.<br\/><strong>Appareils courants<\/strong>\u00a0:<br\/>Disjoncteurs ouverts (ACB), syst\u00e8mes de barres omnibus<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">8. Courant de cr\u00eate admissible nominal (Ipk)<\/h4>\n\n\n\n<p><strong>Unit\u00e9<\/strong>\u00a0: kA (cr\u00eate)<br\/><strong>D\u00e9finition<\/strong>\u00a0: <br\/>Le courant de cr\u00eate instantan\u00e9 maximal pendant un court-circuit.<br\/><strong>Appareils courants<\/strong>\u00a0: <br\/>Barres omnibus, disjoncteurs ouverts (ACB)<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">9. Courant de calibre du ch\u00e2ssis du disjoncteur (Inm)<\/h4>\n\n\n\n<p><strong>Unit\u00e9<\/strong>\u00a0: A<br\/><strong>D\u00e9finition<\/strong>\u00a0: <br\/>Inm est le calibre du ch\u00e2ssis d\u2019un disjoncteur. Il repr\u00e9sente la capacit\u00e9 de courant nominale maximale du ch\u00e2ssis du disjoncteur, d\u00e9finissant la limite sup\u00e9rieure du m\u00e9canisme de commutation et de l\u2019unit\u00e9 de d\u00e9clenchement qui peuvent \u00eatre install\u00e9s dans ce ch\u00e2ssis. <br\/><strong>Comportement de fonctionnement<\/strong>\u00a0:<br\/>Inm lui-m\u00eame n\u2019agit pas comme un seuil de protection ou de d\u00e9clenchement et ne d\u00e9clenche pas directement le fonctionnement du disjoncteur. Au lieu de cela, il d\u00e9finit la capacit\u00e9 structurelle et thermique du ch\u00e2ssis du disjoncteur. Pendant le fonctionnement, le courant nominal r\u00e9el In et les r\u00e9glages de protection (Ir\u00a0\/\u00a0Isd\u00a0\/\u00a0Ii) sont s\u00e9lectionn\u00e9s en fonction de l\u2019unit\u00e9 de d\u00e9clenchement install\u00e9e, mais ils ne peuvent pas d\u00e9passer Inm. Si une unit\u00e9 de d\u00e9clenchement ou une condition de fonctionnement tente de d\u00e9passer le calibre du ch\u00e2ssis, le fonctionnement s\u00fbr et l\u2019int\u00e9grit\u00e9 thermique du disjoncteur ne peuvent \u00eatre garantis.   <br\/><\/p>\n\n\n\n<h4 class=\"wp-block-heading\">10. Courant nominal de groupe (Ing)<\/h4>\n\n\n\n<p><strong>Unit\u00e9<\/strong>\u00a0: A<br\/><strong>D\u00e9finition<\/strong>\u00a0: <br\/>Ing est le courant continu total maximal que plusieurs circuits dans la m\u00eame section d\u2019appareillage de commutation peuvent supporter simultan\u00e9ment, compte tenu de l\u2019interaction thermique et des limites d\u2019\u00e9l\u00e9vation de temp\u00e9rature de l\u2019ensemble.<br\/><strong><strong>Comportement de fonctionnement<\/strong><\/strong>\u00a0:<br\/>Ing ne fournit pas de protection ou de d\u00e9clenchement. Il d\u00e9finit la charge totale admissible pendant le fonctionnement multi-circuits pour \u00e9viter la surchauffe des barres omnibus, des conducteurs et des composants internes. Il est principalement utilis\u00e9 pour la r\u00e9partition de la charge et la conception thermique des appareillages de commutation.  <\/p>\n\n\n\n<p><\/p>\n\n\n\n<h4 class=\"wp-block-heading\">11. Courant nominal de circuit unique (Inc)<\/h4>\n\n\n\n<p><strong>Unit\u00e9<\/strong>\u00a0: A<br\/><strong>D\u00e9finition<\/strong>\u00a0: Le courant continu maximal qu\u2019un seul circuit dans la m\u00eame section d\u2019appareillage de commutation peut supporter lorsque seul ce circuit est aliment\u00e9, l\u2019\u00e9l\u00e9vation de temp\u00e9rature ne d\u00e9passant pas la limite.<br\/><strong><strong>Comportement de fonctionnement<\/strong><\/strong>\u00a0:<br\/>En g\u00e9n\u00e9ral, Inc\u00a0\u2265\u00a0Ing (par circuit), car lorsque plusieurs circuits fonctionnent simultan\u00e9ment, la chaleur g\u00e9n\u00e9r\u00e9e s\u2019accumule et augmente la temp\u00e9rature globale \u00e0 l\u2019int\u00e9rieur de l\u2019armoire. Par cons\u00e9quent, la capacit\u00e9 de transport de courant totale en fonctionnement multi-circuits est inf\u00e9rieure \u00e0 la somme des capacit\u00e9s de transport de courant des circuits individuels, et ainsi le courant nominal de circuit unique Inc est naturellement sup\u00e9rieur au courant nominal de groupe Ing. <br\/><\/p>\n\n\n\n<h4 class=\"wp-block-heading\">12. Courant de court-circuit conditionnel nominal (Icc)<\/h4>\n\n\n\n<p><strong>Unit\u00e9<\/strong>\u00a0: kA<br\/><strong>D\u00e9finition<\/strong>\u00a0: <br\/>Le courant de d\u00e9faut maximal lorsqu\u2019un court-circuit se produit dans le circuit.<br\/><strong><strong>Comportement de fonctionnement<\/strong><\/strong>\u00a0:<br\/>En termes simples, lorsqu\u2019un court-circuit se produit \u00e0 un certain point, Icc est le courant de court-circuit maximal que le syst\u00e8me d\u2019alimentation peut g\u00e9n\u00e9rer \u00e0 ce point dans les pires conditions. Cependant, ce n\u2019est pas toujours absolu\u00a0; dans des conditions de c\u00e2blage r\u00e9elles, des facteurs tels que la longueur des c\u00e2bles et d\u2019autres tol\u00e9rances peuvent faire en sorte que le courant de court-circuit r\u00e9el soit sup\u00e9rieur \u00e0 la valeur nominale. L\u2019Icc nominal indiqu\u00e9 sur l\u2019\u00e9quipement est le \u00ab\u00a0pire des cas dans des conditions id\u00e9ales\u00a0\u00bb, tandis que la situation r\u00e9elle peut \u00eatre plus grave. Par cons\u00e9quent, Icu est g\u00e9n\u00e9ralement s\u00e9lectionn\u00e9 plus haut qu\u2019Icc\u00a0; sinon, des arcs et des \u00e9tincelles peuvent se produire.   <\/p>\n\n\n\n<div class=\"wp-block-uagb-container uagb-layout-grid uagb-block-2cb05b47 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-b6819921\">\n<div class=\"wp-block-uagb-image uagb-block-66e29e3b wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/risentric.com\/wp-content\/uploads\/2026\/04\/Risentric-Products-1-1024x576.webp ,https:\/\/risentric.com\/wp-content\/uploads\/2026\/04\/Risentric-Products-1.webp 780w, https:\/\/risentric.com\/wp-content\/uploads\/2026\/04\/Risentric-Products-1.webp 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/risentric.com\/wp-content\/uploads\/2026\/04\/Risentric-Products-1-1024x576.webp\" alt=\"Produits Risentric\" class=\"uag-image-18214\" width=\"325\" height=\"182\" title=\"Produits Risentric\" loading=\"lazy\" role=\"img\"><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-fc3d7d99\">\n<p class=\"has-text-align-left\" style=\"font-style:italic;font-weight:800;text-transform:capitalize\"><strong><strong>Vous recherchez des appareillages et tableaux test\u00e9s en usine pour votre projet ? <\/strong><\/strong><\/p>\n\n\n\n<div class=\"wp-block-uagb-buttons uagb-buttons__outer-wrap uagb-btn__large-btn uagb-btn-tablet__default-btn uagb-btn-mobile__default-btn uagb-block-9ca4ba33\"><div class=\"uagb-buttons__wrap uagb-buttons-layout-wrap \">\n<div class=\"wp-block-uagb-buttons-child uagb-buttons__outer-wrap uagb-block-1dde673e wp-block-button\"><div class=\"uagb-button__wrapper\"><a class=\"uagb-buttons-repeater wp-block-button__link\" aria-label=\"\" href=\"https:\/\/risentric.com\/fr\/produits-et-services\/appareillage-armoire-panneau\/distribution-basse-tension\/\" rel=\"follow noopener\" target=\"_self\" role=\"button\"><div class=\"uagb-button__link\"><strong>D\u00e9couvrez nos solutions d\u2019appareillage de commutation\/tableau de distribution.<\/strong><\/div><span class=\"uagb-button__icon uagb-button__icon-position-after\"><svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" aria-hidden=\"true\" focussable=\"false\"><path d=\"M438.6 278.6l-160 160C272.4 444.9 264.2 448 256 448s-16.38-3.125-22.62-9.375c-12.5-12.5-12.5-32.75 0-45.25L338.8 288H32C14.33 288 .0016 273.7 .0016 256S14.33 224 32 224h306.8l-105.4-105.4c-12.5-12.5-12.5-32.75 0-45.25s32.75-12.5 45.25 0l160 160C451.1 245.9 451.1 266.1 438.6 278.6z\"><\/path><\/svg><\/span><\/a><\/div><\/div>\n<\/div><\/div>\n<\/div>\n<\/div><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Param\u00e8tres de tension et de fr\u00e9quence<\/h3>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-6043e4d8 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/risentric.com\/wp-content\/uploads\/2026\/01\/Voltage-and-Frequency-related-1024x683.webp ,https:\/\/risentric.com\/wp-content\/uploads\/2026\/01\/Voltage-and-Frequency-related.webp 780w, https:\/\/risentric.com\/wp-content\/uploads\/2026\/01\/Voltage-and-Frequency-related.webp 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/risentric.com\/wp-content\/uploads\/2026\/01\/Voltage-and-Frequency-related-1024x683.webp\" alt=\"Relatif \u00e0 la tension et \u00e0 la fr\u00e9quence\" class=\"uag-image-10574\" width=\"600\" height=\"400\" title=\"Relatif \u00e0 la tension et \u00e0 la fr\u00e9quence\" loading=\"lazy\" role=\"img\"><\/figure><\/div>\n\n\n\n<h4 class=\"wp-block-heading\">1. Tension nominale du syst\u00e8me (Un)<\/h4>\n\n\n\n<p><strong>Unit\u00e9<\/strong>\u00a0: Volt (V) ou kV<br\/><strong>D\u00e9finition<\/strong>\u00a0:<br\/>Un est la tension nominale du syst\u00e8me d\u2019alimentation \u00e0 un point donn\u00e9. Il d\u00e9finit la classe de tension du r\u00e9seau \u00e9lectrique et sert de valeur de r\u00e9f\u00e9rence pour la conception du syst\u00e8me, la s\u00e9lection de l\u2019\u00e9quipement et la coordination. Un est un param\u00e8tre au niveau du syst\u00e8me et ne repr\u00e9sente pas la tension de fonctionnement exacte \u00e0 tout moment.  <br\/><strong>Comportement de fonctionnement<\/strong>\u00a0:<br\/>Un ne limite ni ne r\u00e9gule la tension r\u00e9elle du syst\u00e8me et ne d\u00e9clenche aucune protection. En fonctionnement normal, la tension r\u00e9elle peut fluctuer au-dessus ou en dessous de Un dans la plage de tol\u00e9rance admissible du syst\u00e8me d\u2019alimentation. Tous les \u00e9quipements \u00e9lectriques connect\u00e9s doivent avoir des tensions de fonctionnement et d\u2019isolation nominales \u00e9gales ou sup\u00e9rieures \u00e0 Un pour assurer un fonctionnement s\u00fbr et fiable.  <\/p>\n\n\n\n<h4 class=\"wp-block-heading\">2. Tension de fonctionnement nominale (Ue)<\/h4>\n\n\n\n<p><strong>Unit\u00e9<\/strong>\u00a0: Volt (V) ou kV<br\/><strong>D\u00e9finition<\/strong>\u00a0: <br\/>Un est la tension nominale du syst\u00e8me d\u2019alimentation \u00e0 un point donn\u00e9. Il d\u00e9finit la classe de tension du r\u00e9seau \u00e9lectrique et sert de valeur de r\u00e9f\u00e9rence pour la conception du syst\u00e8me, la s\u00e9lection de l\u2019\u00e9quipement et la coordination. Un est un param\u00e8tre au niveau du syst\u00e8me et ne repr\u00e9sente pas la tension de fonctionnement exacte \u00e0 tout moment.  <br\/><strong>Comportement de fonctionnement<\/strong>\u00a0:<br\/>Un ne limite ni ne r\u00e9gule la tension r\u00e9elle du syst\u00e8me et ne d\u00e9clenche aucune protection. En fonctionnement normal, la tension r\u00e9elle peut fluctuer au-dessus ou en dessous de Un dans la plage de tol\u00e9rance admissible du syst\u00e8me d\u2019alimentation. Tous les \u00e9quipements \u00e9lectriques connect\u00e9s doivent avoir des tensions de fonctionnement et d\u2019isolation nominales \u00e9gales ou sup\u00e9rieures \u00e0 Un pour assurer un fonctionnement s\u00fbr et fiable.  <\/p>\n\n\n\n<h4 class=\"wp-block-heading\">3. Tension d\u2019isolement nominale (Ui)<\/h4>\n\n\n\n<p><strong>Unit\u00e9\u00a0:<\/strong> V ou kV<br\/><strong>D\u00e9finition<\/strong>\u00a0:<br\/>Ui est la tension d\u2019isolement nominale de l\u2019\u00e9quipement \u00e9lectrique. Il repr\u00e9sente la tension maximale que le syst\u00e8me d\u2019isolation de l\u2019\u00e9quipement peut supporter en continu dans des conditions sp\u00e9cifi\u00e9es sans d\u00e9gradation de l\u2019isolation. Ui est d\u00e9termin\u00e9 par des facteurs de conception d\u2019isolation tels que la distance dans l\u2019air, la distance de fuite, les mat\u00e9riaux isolants et la structure interne.  <br\/><strong>Comportement de fonctionnement<\/strong>\u00a0:<br\/>Ui n\u2019est pas un param\u00e8tre de fonctionnement ou de protection et ne d\u00e9clenche aucune action de protection. En fonctionnement normal, la tension du syst\u00e8me (Un) et la tension de fonctionnement nominale de l\u2019\u00e9quipement (Ue) doivent rester inf\u00e9rieures \u00e0 Ui pour assurer l\u2019int\u00e9grit\u00e9 de l\u2019isolation \u00e0 long terme. Si Ui est d\u00e9pass\u00e9, une d\u00e9charge partielle, une fuite de surface ou une d\u00e9faillance de l\u2019isolation peuvent se produire, ce qui peut entra\u00eener des courts-circuits, des dommages \u00e0 l\u2019\u00e9quipement ou des d\u00e9fauts d\u2019arc.  <br\/><\/p>\n\n\n\n<h4 class=\"wp-block-heading\">4. Tension de tenue aux chocs nominaux (Uimp)<\/h4>\n\n\n\n<p><strong>Unit\u00e9\u00a0:<\/strong> kV (cr\u00eate)<br\/><strong>D\u00e9finition<\/strong>\u00a0: <br\/>Uimp est la tension de tenue aux chocs nominaux de l\u2019\u00e9quipement \u00e9lectrique. Il repr\u00e9sente la valeur de cr\u00eate maximale de la surtension transitoire, telle que les impulsions de foudre ou les surtensions de commutation, que le syst\u00e8me d\u2019isolation de l\u2019\u00e9quipement peut supporter pendant une tr\u00e8s courte dur\u00e9e sans contournement ou d\u00e9faillance de l\u2019isolation. <br\/><strong>Comportement de fonctionnement<\/strong>\u00a0:<br\/>Uimp s\u2019applique uniquement aux conditions transitoires et n\u2019est pas li\u00e9 au fonctionnement continu. Il ne r\u00e9gule pas la tension et ne lance pas de fonctions de protection. Lorsque les surtensions impulsionnelles restent dans la limite de Uimp, le syst\u00e8me d\u2019isolation maintient son int\u00e9grit\u00e9. Si Uimp est d\u00e9pass\u00e9, un contournement ou une d\u00e9faillance de l\u2019isolation interne peut se produire, ce qui peut entra\u00eener des d\u00e9fauts d\u2019arc, des dommages \u00e0 l\u2019\u00e9quipement ou une d\u00e9faillance, m\u00eame si la tension en r\u00e9gime permanent reste dans les limites de Ui et Ue.   <\/p>\n\n\n\n<h4 class=\"wp-block-heading\">5. Fr\u00e9quence nominale (fn\u00a0\/\u00a0f)<\/h4>\n\n\n\n<p><strong>Unit\u00e9<\/strong>\u00a0: Hertz (Hz)<br\/><strong>D\u00e9finition<\/strong>\u00a0:<br\/>fn (ou f) est la fr\u00e9quence nominale du syst\u00e8me d\u2019alimentation pour lequel l\u2019\u00e9quipement \u00e9lectrique est con\u00e7u pour fonctionner en continu dans des conditions normales sp\u00e9cifi\u00e9es. Il d\u00e9finit la fr\u00e9quence nominale de l\u2019alimentation CA et sert de r\u00e9f\u00e9rence pour la conception, les performances et les caract\u00e9ristiques thermiques de l\u2019\u00e9quipement. <br\/><strong>Comportement de fonctionnement<\/strong>\u00a0:<br\/>Lorsque la fr\u00e9quence du syst\u00e8me reste \u00e0 ou pr\u00e8s de la valeur nominale fn, l\u2019\u00e9quipement fonctionne normalement avec ses performances \u00e9lectriques, thermiques et m\u00e9caniques maintenues. Des \u00e9carts de fr\u00e9quence mod\u00e9r\u00e9s sont g\u00e9n\u00e9ralement autoris\u00e9s pendant de courtes dur\u00e9es, selon les normes du syst\u00e8me. Un \u00e9cart important ou prolong\u00e9 par rapport \u00e0 fn peut entra\u00eener des pertes accrues, un chauffage anormal, une efficacit\u00e9 r\u00e9duite ou un dysfonctionnement, mais fn lui-m\u00eame ne fournit pas de r\u00e9gulation ou de protection de la fr\u00e9quence.  <\/p>\n\n\n\n<h3 class=\"wp-block-heading\">FAQ (D\u00e9finition des param\u00e8tres de l\u2019appareillage)<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\">1) Que sont les \u00ab param\u00e8tres de l\u2019appareillage \u00bb ?<\/h4>\n\n\n\n<p>Les param\u00e8tres de l\u2019appareillage sont des caract\u00e9ristiques \u00e9lectriques et m\u00e9caniques normalis\u00e9es utilis\u00e9es pour <strong>s\u00e9lectionner, sp\u00e9cifier, tester et exploiter<\/strong> l\u2019appareillage en toute s\u00e9curit\u00e9. Ils d\u00e9crivent ce que l\u2019\u00e9quipement peut supporter en continu (courant), supporter ou interrompre lors de d\u00e9fauts (pouvoir de coupure) et tol\u00e9rer \u00e9lectriquement (niveaux de tension\/isolation et d\u2019impulsion). <\/p>\n\n\n\n<h4 class=\"wp-block-heading\">2) Quelle est la diff\u00e9rence entre <strong>In<\/strong> et <strong>Inm<\/strong> ?<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>In (courant assign\u00e9)<\/strong> est le <strong>courant permanent<\/strong> que l\u2019appareil peut supporter dans des conditions sp\u00e9cifi\u00e9es.<\/li>\n\n\n\n<li><strong>Inm (courant de taille de ch\u00e2ssis)<\/strong> est la <strong>capacit\u00e9 maximale de la carcasse du disjoncteur<\/strong>. Il ne s\u2019agit pas d\u2019une valeur de d\u00e9clenchement ; il d\u00e9finit la limite sup\u00e9rieure du d\u00e9clencheur et des r\u00e9glages pouvant \u00eatre appliqu\u00e9s \u00e0 ce ch\u00e2ssis. <\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">3) Quelle est la diff\u00e9rence entre <strong>In<\/strong> et <strong>Ir<\/strong> ?<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>In<\/strong> est le courant permanent assign\u00e9 de l\u2019appareil (valeur de la plaque signal\u00e9tique).<\/li>\n\n\n\n<li><strong>Ir<\/strong> est le <strong>r\u00e9glage de protection long retard<\/strong> (seuil de surcharge) du d\u00e9clencheur. En pratique, <strong>Ir est r\u00e9glable<\/strong> (souvent exprim\u00e9 comme une fraction de In ou Inm selon le type de disjoncteur). <\/li>\n<\/ul>\n<\/div><\/div>\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>-Pour les param\u00e8tres li\u00e9s aux enveloppes, tels que l\u2019indice IP, la conception structurelle et les conditions d\u2019installation, veuillez vous r\u00e9f\u00e9rer [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":7962,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"enabled","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[151],"tags":[152,158,155,153,157,154,156],"class_list":["post-7958","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-normes-et-parametres-electriques","tag-appareillage-de-commutation","tag-appareillage-de-commutation-bt","tag-courant-nominal","tag-disjoncteur","tag-normes-cei","tag-parametres-electriques","tag-protection-contre-les-courts-circuits"],"acf":[],"spectra_custom_meta":{"_pingme":["1"],"_encloseme":["1"],"rank_math_internal_links_processed":["1"],"_alp_processed":["1779719471"],"ast-main-header-display":[""],"ast-hfb-above-header-display":[""],"ast-hfb-below-header-display":[""],"ast-hfb-mobile-header-display":[""],"adv-header-id-meta":[""],"footer-sml-layout":[""],"stick-header-meta":[""],"header-main-stick-meta":[""],"header-above-stick-meta":[""],"header-below-stick-meta":[""],"site-post-title":[""],"site-sidebar-layout":["default"],"site-content-layout":[""],"ast-featured-img":[""],"ast-breadcrumbs-content":[""],"theme-transparent-header-meta":["enabled"],"ast-banner-title-visibility":[""],"ast-global-header-display":[""],"ast-site-content-layout":["default"],"site-content-style":["default"],"site-sidebar-style":["default"],"_top_nav_excluded":[""],"_cms_nav_minihome":[""],"_thumbnail_id":["7962"],"_last_translation_edit_mode":["translation-editor"],"_wpml_word_count":["2442"],"rank_math_analytic_object_id":["117"],"_wpml_media_has_media":["1"],"rank_math_title":["Explication des param\u00e8tres de l\u2019appareillage : courant, tension et caract\u00e9ristiques CEI | Risentric"],"rank_math_description":["Explication des param\u00e8tres de l\u2019appareillage : In, Ir, Isd, Ii, Icu\/Ics, Icw, Ipk, ainsi que Un, Ue, Ui, Uimp et la fr\u00e9quence \u2014 signification de chaque caract\u00e9ristique sur les fiches techniques d\u2019appareillage CEI."],"rank_math_focus_keyword":["Param\u00e8tres de lappareillage"],"_uagb_toc_options":["a:2:{s:17:\"_uagb_toc_version\";s:10:\"1780536371\";s:18:\"_uagb_toc_headings\";a:23:{i:0;a:4:{s:5:\"level\";i:3;s:2:\"id\";s:28:\"param\u00e8tres-li\u00e9s-au-courant\";s:7:\"content\";s:28:\"Param\u00e8tres li\u00e9s au courant\";s:5:\"depth\";i:3;}i:1;a:4:{s:5:\"level\";i:4;s:2:\"id\";s:20:\"1-courant-nominal-in\";s:7:\"content\";s:23:\"1. Courant nominal (In)\";s:5:\"depth\";i:4;}i:2;a:4:{s:5:\"level\";i:4;s:2:\"id\";s:39:\"2-courant-de-r\u00e9glage-du-d\u00e9lai-long-ir\";s:7:\"content\";s:42:\"2. Courant de r\u00e9glage du d\u00e9lai long (Ir)\";s:5:\"depth\";i:4;}i:3;a:4:{s:5:\"level\";i:4;s:2:\"id\";s:41:\"3-courant-de-r\u00e9glage-du-d\u00e9lai-court-isd\";s:7:\"content\";s:44:\"3. Courant de r\u00e9glage du d\u00e9lai court (Isd)\";s:5:\"depth\";i:4;}i:4;a:4:{s:5:\"level\";i:4;s:2:\"id\";s:42:\"4-courant-de-d\u00e9clenchement-instantan\u00e9-ii\";s:7:\"content\";s:45:\"4. Courant de d\u00e9clenchement instantan\u00e9 (Ii)\";s:5:\"depth\";i:4;}i:5;a:4:{s:5:\"level\";i:4;s:2:\"id\";s:56:\"5-pouvoir-de-coupure-ultime-en-court-circuit-nominal-icu\";s:7:\"content\";s:59:\"5. Pouvoir de coupure ultime en court-circuit nominal (Icu)\";s:5:\"depth\";i:4;}i:6;a:4:{s:5:\"level\";i:4;s:2:\"id\";s:60:\"6-pouvoir-de-coupure-en-court-circuit-de-service-nominal-ics\";s:7:\"content\";s:63:\"6. Pouvoir de coupure en court-circuit de service nominal (Ics)\";s:5:\"depth\";i:4;}i:7;a:4:{s:5:\"level\";i:4;s:2:\"id\";s:49:\"7-courant-admissible-de-courte-dur\u00e9e-nominal-icw\";s:7:\"content\";s:52:\"7. Courant admissible de courte dur\u00e9e nominal (Icw)\";s:5:\"depth\";i:4;}i:8;a:4:{s:5:\"level\";i:4;s:2:\"id\";s:42:\"8-courant-de-cr\u00eate-admissible-nominal-ipk\";s:7:\"content\";s:45:\"8. Courant de cr\u00eate admissible nominal (Ipk)\";s:5:\"depth\";i:4;}i:9;a:4:{s:5:\"level\";i:4;s:2:\"id\";s:51:\"9-courant-de-calibre-du-ch\u00e2ssis-du-disjoncteur-inm\";s:7:\"content\";s:54:\"9. Courant de calibre du ch\u00e2ssis du disjoncteur (Inm)\";s:5:\"depth\";i:4;}i:10;a:4:{s:5:\"level\";i:4;s:2:\"id\";s:32:\"10-courant-nominal-de-groupe-ing\";s:7:\"content\";s:35:\"10. Courant nominal de groupe (Ing)\";s:5:\"depth\";i:4;}i:11;a:4:{s:5:\"level\";i:4;s:2:\"id\";s:40:\"11-courant-nominal-de-circuit-unique-inc\";s:7:\"content\";s:43:\"11. Courant nominal de circuit unique (Inc)\";s:5:\"depth\";i:4;}i:12;a:4:{s:5:\"level\";i:4;s:2:\"id\";s:52:\"12-courant-de-court-circuit-conditionnel-nominal-icc\";s:7:\"content\";s:55:\"12. Courant de court-circuit conditionnel nominal (Icc)\";s:5:\"depth\";i:4;}i:13;a:4:{s:5:\"level\";i:3;s:2:\"id\";s:39:\"param\u00e8tres-de-tension-et-de-fr\u00e9quence\";s:7:\"content\";s:39:\"Param\u00e8tres de tension et de fr\u00e9quence\";s:5:\"depth\";i:3;}i:14;a:4:{s:5:\"level\";i:4;s:2:\"id\";s:33:\"1-tension-nominale-du-syst\u00e8me-un\";s:7:\"content\";s:36:\"1. Tension nominale du syst\u00e8me (Un)\";s:5:\"depth\";i:4;}i:15;a:4:{s:5:\"level\";i:4;s:2:\"id\";s:39:\"2-tension-de-fonctionnement-nominale-ue\";s:7:\"content\";s:42:\"2. Tension de fonctionnement nominale (Ue)\";s:5:\"depth\";i:4;}i:16;a:4:{s:5:\"level\";i:4;s:2:\"id\";s:32:\"3-tension-disolement-nominale-ui\";s:7:\"content\";s:38:\"3. Tension d\u2019isolement nominale (Ui)\";s:5:\"depth\";i:4;}i:17;a:4:{s:5:\"level\";i:4;s:2:\"id\";s:42:\"4-tension-de-tenue-aux-chocs-nominaux-uimp\";s:7:\"content\";s:45:\"4. Tension de tenue aux chocs nominaux (Uimp)\";s:5:\"depth\";i:4;}i:18;a:4:{s:5:\"level\";i:4;s:2:\"id\";s:25:\"5-fr\u00e9quence-nominale-fnf\";s:7:\"content\";s:33:\"5. Fr\u00e9quence nominale (fn\u00a0\/\u00a0f)\";s:5:\"depth\";i:4;}i:19;a:4:{s:5:\"level\";i:3;s:2:\"id\";s:48:\"faq-d\u00e9finition-des-param\u00e8tres-de-lappareillage\";s:7:\"content\";s:53:\"FAQ (D\u00e9finition des param\u00e8tres de l\u2019appareillage)\";s:5:\"depth\";i:3;}i:20;a:4:{s:5:\"level\";i:4;s:2:\"id\";s:43:\"1-que-sont-les-param\u00e8tres-de-lappareillage\";s:7:\"content\";s:55:\"1) Que sont les \u00ab param\u00e8tres de l\u2019appareillage \u00bb ?\";s:5:\"depth\";i:4;}i:21;a:4:{s:5:\"level\";i:4;s:2:\"id\";s:43:\"2-quelle-est-la-diff\u00e9rence-entre-in-et-inm\";s:7:\"content\";s:46:\"2) Quelle est la diff\u00e9rence entre In et Inm ?\";s:5:\"depth\";i:4;}i:22;a:4:{s:5:\"level\";i:4;s:2:\"id\";s:42:\"3-quelle-est-la-diff\u00e9rence-entre-in-et-ir\";s:7:\"content\";s:45:\"3) Quelle est la diff\u00e9rence entre In et Ir ?\";s:5:\"depth\";i:4;}}}"]},"uagb_featured_image_src":{"full":["https:\/\/risentric.com\/wp-content\/uploads\/2026\/01\/18aebb31-24a8-4cd5-8172-30a57d349d58_\u7ed3\u679c.webp",1024,1024,false],"thumbnail":["https:\/\/risentric.com\/wp-content\/uploads\/2026\/01\/18aebb31-24a8-4cd5-8172-30a57d349d58_\u7ed3\u679c-150x150.webp",150,150,true],"medium":["https:\/\/risentric.com\/wp-content\/uploads\/2026\/01\/18aebb31-24a8-4cd5-8172-30a57d349d58_\u7ed3\u679c-300x300.webp",300,300,true],"medium_large":["https:\/\/risentric.com\/wp-content\/uploads\/2026\/01\/18aebb31-24a8-4cd5-8172-30a57d349d58_\u7ed3\u679c-768x768.webp",768,768,true],"large":["https:\/\/risentric.com\/wp-content\/uploads\/2026\/01\/18aebb31-24a8-4cd5-8172-30a57d349d58_\u7ed3\u679c.webp",1024,1024,false],"1536x1536":["https:\/\/risentric.com\/wp-content\/uploads\/2026\/01\/18aebb31-24a8-4cd5-8172-30a57d349d58_\u7ed3\u679c.webp",1024,1024,false],"2048x2048":["https:\/\/risentric.com\/wp-content\/uploads\/2026\/01\/18aebb31-24a8-4cd5-8172-30a57d349d58_\u7ed3\u679c.webp",1024,1024,false]},"uagb_author_info":{"display_name":"Risentric","author_link":"https:\/\/risentric.com\/fr\/author\/mythsky126\/"},"uagb_comment_info":0,"uagb_excerpt":"-Pour les param\u00e8tres li\u00e9s aux enveloppes, tels que l\u2019indice IP, la conception structurelle et les conditions d\u2019installation, veuillez vous r\u00e9f\u00e9rer [&hellip;]","_links":{"self":[{"href":"https:\/\/risentric.com\/fr\/wp-json\/wp\/v2\/posts\/7958","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/risentric.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/risentric.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/risentric.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/risentric.com\/fr\/wp-json\/wp\/v2\/comments?post=7958"}],"version-history":[{"count":5,"href":"https:\/\/risentric.com\/fr\/wp-json\/wp\/v2\/posts\/7958\/revisions"}],"predecessor-version":[{"id":21016,"href":"https:\/\/risentric.com\/fr\/wp-json\/wp\/v2\/posts\/7958\/revisions\/21016"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/risentric.com\/fr\/wp-json\/wp\/v2\/media\/7962"}],"wp:attachment":[{"href":"https:\/\/risentric.com\/fr\/wp-json\/wp\/v2\/media?parent=7958"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/risentric.com\/fr\/wp-json\/wp\/v2\/categories?post=7958"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/risentric.com\/fr\/wp-json\/wp\/v2\/tags?post=7958"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}